bintec R3002
29.10.2013
Subject to technical alterations
Page 9 / 11
Teldat GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany
Phone: +49 - 911 9673-0 - Telefax: +49 - 911 688 07 25
Administration / Management
SNMP SNMP (v1, v2, v3), USM model, VACM views, SNMP traps (v1, v2, v3) configurable, SNMP IP access
list configurable
SNMP configuration Complete management with MIB-II, MIB 802.11, Enterprise MIB
Configuration export and import Load and save configurations, optional encrypted; optional automatic control via scheduler
SSH login Supports SSH V1.5 and SSH V2.0 for secure connections of terminal applications
HP OpenView Integration into Network Node Manager
XAdmin Support of XAdmin roll out and configuration managemant tool for larger router installations
(IP+ISDN+GSM)
Interfaces
Ethernet 5 x 10/100/1000 Mbps Ethernet Twisted Pair, autosensing, Auto MDI/MDI-X, up to 4 ports can be
switches as additional WAN ports incl. load balancing, all Ethernet ports can be configured as LAN
or WAN.
Serial console Serial console interface / COM port (mini USB): optional, connection of an analogue / GPRS modem
is possible (supported modems: see www.teldat.de)
ADSL/ADSL 2+ ADSL over ISDN (compatible to U-R2 connection of Deutsche Telekom)
ADSL/ADSL 2+ ADSL over POTS
ISDN Basic Rate (BRI) 1 x BRI (TE), 2 B channels
Hardware
19 inch Mountable in 19 inch rack, incl. 19 inch rack mount kit
Realtime clock System time persists even at power failure for some hours.
Environment Temperature range: Operational 0°C to 40°C; storage -10°C to 70°C; Max. rel. humidity 10 - 95%
(non condensing)
Power supply Integrated wide range power supply 110-240V, with energy efficient swiching controller
Power consumption Max. 15 Watt, typ. 13 Watt
Housing 19 inch 1 high unit metal case, screw-on 19 inch mounting-angle, LEDs and network connectors at
front side
Dimension Ca. 485.6 mm x 220 mm x 45 mm (W x H x D)
Weight Ca. 2600g
Fan Fanless design therefor high MTBF
Reset button Restart or reset to factory state possible
Standards and certifications R&TTE directive 1999/5/EG; EN 55022; EN 55024 + EN 55024/A1; EN61000-3-2; EN 61000-3-3; EN
61000-4-4; EN 60950-1; EN 300 328
Content of Delivery